Simulation Medical Future

Home / Simulators / VIST G7

Mentice · Endovascular interventions

VIST® G7

Twenty-seven modules — from neurovascular thrombectomy to aortic endograft. With the original catheters and guidewires used in the suite.

The Mentice VIST G7 simulator for endovascular interventions

HAPTICS

Force feedback
with wide range

DEVICES

up to 5 simultaneously
(G7+)

INSTRUMENTS

Original catheters,
guidewires and stents

MONITOR

21,5″ Full HD
plus touch-screen laptop

TRANSPORT

two cases, 18 and 22 kg
carry-on compliant

VALIDITY

Face, construct
and concurrent

The training content, in full

Seven areas.
Twenty-seven modules.
And the numbers are Mentice's.

The numbers are taken from the Mentice module and case review, 2024 edition. All modules except Echo Trainer run on the VIST G5, G7 and G7+ hardware.

Peripheral interventions

ANGIOGRAPHY · ILIAC AND SFA · BTK · RENAL

61

4 modules

AVAILABLE

Neurovascular interventions

COILING · THROMBECTOMY · STROKE · CAROTID

53

5 modules

AVAILABLE

Coronary interventions

FROM BASICS TO BIFURCATION STENTING

34

3 modules

AVAILABLE

Structural and electrophysiology

CRM · TRANSSEPTAL PUNCTURE · LAAO · TAVI

33

6 modules

AVAILABLE

Embolotherapy

UAE · PAE · TACE · VASCULAR TRAUMA

25

4 modules

AVAILABLE

Aortic interventions

EVAR · TEVAR

16

2 modules

AVAILABLE

Multidisciplinary

TRANSRADIAL ACCESS · RENAL DENERVATION · RADIATION PROTECTION

9

3 modules

AVAILABLE

TOTAL

232

PATIENT CASES
IN 27 MODULES

The figure 232 is the manufacturer's. We verified it: the sum of the seven areas from its own data gives 231. The difference is one case and is unexplained in the source — we have asked Mentice. Until then both figures appear here.

27

MODULES

7

AREAS

What others cannot do

Bifurcation requires
two hands and two devices.

In bifurcation stenting, balloon-assisted coiling or the buddy wire technique two devices work simultaneously in the vessel. VIST® G7+ drives them in parallel — up to five at once — using Mentice's patented technology.

  • Bifurcation stenting with two guidewires
  • Balloon-assisted and stent-assisted coiling
  • Buddy wire technique
  • Deployment of side-branch devices
The internal mechanism of VIST G7 showing the channels for catheters and guidewires

Where minutes are brain

Thrombectomy in
ischaemic stroke.

Nine cases for thrombectomy alone, plus six for the full intervention in acute ischaemic stroke and twenty-two for the carotid vessels.

  • Five different anatomies, including severely tortuous vessels
  • Occlusions left and right, MCA (M1)
  • Direct aspiration and ADAPT technique
  • Deployment, positioning and safe retrieval of a stent retriever
  • Working with C-arm, biplane and magnification to assess the thrombus
  • The Simmons manoeuvre and microcatheter exchange as separate exercises

All cases have step-by-step guidance. The accompanying iPad application lets the course director trigger a complication in real time.

Angiographic view of the carotid and cerebral vessels in the simulation
Aortic endograft deployed in a simulated aortic arch

Aortic interventions

EVAR and TEVAR —
sixteen cases.

Ten cases for endovascular repair of the abdominal aorta and six for the thoracic. Endograft positioning, sizing and deployment — in anatomies that do not forgive mistakes.

10

EVAR

6

TEVAR

Around the device

EXTENSIONS AND PLATFORMS

01

VIST® Lab

The stationary platform: realistic workflow and training for the entire team, not only the interventionalist.

02

G7 Extension

Second leg for bifemoral access. Both fit in one case.

03

VIST® Case-It

The specific patient's anatomy is imported and assembled on a template to a complete anatomy — for rehearsal before the intervention itself.

04

Virtual Patient Link

The simulation runs directly through the angiography equipment — with the real console and the real monitor in the suite.

05

TEE Add-on

Transoesophageal echocardiography for the structural modules; Echo Trainer is the only module with separate hardware.

06

Accessories

Pedal from a real angiography suite, haptic syringe, indeflator and stent release handle.

FOR PUBLIC TENDERS

Documentation is also available in Bulgarian.

The product sheets, the module and case review, and the CE certificate for VIST® G7 exist in a Bulgarian version — translated as part of a procedure before the Ministry of Health. We supply them when preparing a technical specification.

If you need a comparison with the requirements of a specific procedure, we carry it out before the proposal — together with the assessment of whether the device actually suits your training programme.

Get in touch

Independent assessment

An endovascular programme depends on case volume and on a team. Before the proposal we clarify whether VIST® G7 is the right step for your hospital — including when the answer is “not yet”.

To the needs assessment

We bring VIST® G7 to you.

The device travels in two cases. The demonstration takes place in your suite, with your residents at the guidewires.